    The general objective of 26 GHz. Pulse Radar Level Transmitter provides continuous level measurement up to 32.8 ‘(10m) with a 4-20mA signal output, and is configured via its built-in push button display module. The non-contact liquid level sensor is for the above chemical or metal grade water storage applications or reinforced concrete tanks or underneath the quality tanks of all materials. Select this sensor for easy application conditions with corrosive media, slight agitation, condensation or steam, and installation in a low profile adapter tank or mounting flange.

    Characteristics

    PTFE encapsulated antenna and mounting for corrosive media

    Simple Button Configuration Button Display Module

    26 GHz. Pulse radar is affected by steam or condensation

    12 “(30cm) dead band allows the use of the entire tank

    LCD displays level in feet or meters with percent bar span

    Optional display mode indicates the return curve of the echo signal

    Automatic temperature compensation for precise measurement

    Fail-safe diagnostic outputs with selectable fail-safe signal

    Recognition, storage and rejection of the false echo signal

    Robust IP67 aluminum housing with polycarbonate window

    Characteristics

    Range: 12 “to 32.8” (30cm to 10m)
    Frequency: 26 GHz.
    Accuracy: 5mm ±
    Dead band: 12 “(30cm)
    Beam angle: 19 °
    Configuration: Pushbutton
    Memory: Non-volatile
    Display Type: LCD, dot matrix
    Display units: The feet and the meters
    Display bar: Percent of scale
    View chart: Signal curve Echo
    Supply voltage: 16-26 VDC
    Max. consumption: 22.5 mA
    Signal output: 4-20 mA, two-wire
    Inverted signal: 4-20 mA, 20-4 mA
    Signal fail-safe: 3.9 mA, 20.5 mA, 22 mA
    Temp Process: F: -40 ° to 266 °
    C: -40 ° to 130 °
    Temp. Comp.: Automatic
    Storage temperature: F: -40 ° to 176 °
    C: -40 ° to 80 °
    Pressure: -14.5 to 43.5 psi (-1 to 3 bar)
    Protection sign: IP67
    Pj. Equipment: Aluminum w / silicone seal,
    neck PBT FR & Wrench
    Pj. Window mats.: Polycarbonate
    Input Conduit: (1) 1/2 “NPT connector
    (1) M20 x 1,5 cap
    Antenna equipment: PTFE
    Assembly process: 1 1/2 “NPT
    Classification: Main objective
    Certification: cTUVus
    FCC
    Conformity: CE, RoHS

    – See more at: http://www.flowline.com/echopulse_lr10.php#sthash.njNFUqWU.dpuf